How to reset sharp AR -5618 - Sharp AR-5320 Black and White Copier


enter simulation: pound, interrupt, clear, interrupt, then enter 14, press start,press execute on touch screen, press ca until copier restarts, this is a general clear code, if problem returns you will have a heat problem in the fuser.

reset the drum?

How To Reset The Drum Code For Sharp Ar-5623, Ar-5620, Ar-5620s, Ar-5618n, Ar-5618s, Ar-5620n, Ar-5623n, Ar-5618d, Ar-5620d, Ar-5623d.


Have you done simulation 24-7 to reset the drum? Do SIM 24-7 and the unit will start to copy


How To Reset Total Counter For Sharp Ar-5623, Ar-5620, Ar-5620s, Ar-5618n, Ar-5618s, Ar-5620n, Ar-5623n, Ar-5618d, Ar-5620d, Ar-5623d.

How to reset Total counter on sharp AR-5618/5620 copier


Perform the following procedure to enter the simulation mode."#" key Interrupt key "C" key Interrupt key, then, then enter 24 start 7 start, then you can clear the drum count.Press 42, start, 01, start for clearing developer counter, and after clearing all this you have to press 'ca' to exit this mode, rate this and vote for this.


How To Reset Total Counter For Sharp Ar-5623, Ar-5620, Ar-5620s, Ar-5618n, Ar-5618s, Ar-5620n, Ar-5623n, Ar-5618d, Ar-5620d, Ar-5623d.



AR-5127 Counter Reset

1.Press continously #key then Interrupt key then CA key then # key

2.If the display turns off it means that you are inside the simulation but if not do again step 1.


3.Press 81 then press enter then press 1 then enter


Hope that this will help to reset .


How To Reset Maintenance indicator sign For Sharp Ar-5623, Ar-5620, Ar-5620s, Ar-5618n, Ar-5618s, Ar-5620n, Ar-5623n, Ar-5618d, Ar-5620d, Ar-5623d.

How to reset the Maintenance indicator sign in SHARP AR 5618


1. Entering the simulation mode
Perform the following procedure to enter the simulation mode.
"#" key "*" key "C" key "*" key

Main code 14 Start key Sub code 0 Start key

OR

"#" key "INTERRUPT" key "C" key "INTERRUPT"

Main code 14 Start key Sub code 0 Start key

2. Canceling the simulation mode
When the clear all key is pressed, the simulation mode is cancelled.
When the

* After canceling the simulation mode, be sure to turn OFF/ON the
power and check the operation.